- Turn on the vacuum function.
- Feed out an additional foot of media.
- Press the down arrow key for 2 seconds.
- Wait 5 seconds.
- Repeat until enough film is fed out to ensure final prints cure properly.
- Turn off the front heating plate.
- Turn off the powder recirculation.
- Cut the media while pulling slightly to prevent crinkling.
- Manually feed the remaining film into the shaker.
- Slowly open the center lid.
- Hold the film from the center opening to maintain control.
- Wait until the last print is fully powdered before releasing the film.
- Set the shaker to Manual mode.
- Monitor curing as the last print passes through the shaking zone.
- Turn off the shaking function once the last print exits the conveyor belt area.
- Apply tension to the film to slow the take-up reel.
- Prevent the film from rolling up too quickly.
- Turn off the take-up system.
- Turn off the main heat.
- Turn off the sub heat.
- Turn off the vacuum.
- Turn off the conveyor.
Powder Recovery and Cleaning
- Turn on the vacuum function to pull powder from the bottom to the top powder station.
- Brush off excess powder.
- Place the end-of-day tray over the vacuum area.
- Press and hold the cleaning button for more than 5 seconds to expel remaining powder.
- Use the provided spatula to tap inside the powdering station.
- Brush powder into the tray.
- Pour recovered powder into a sealed container with desiccant.
- Vacuum remaining powder around the machine.
- Leave the air purifier running for at least 5 minutes before disconnecting.
- Clean the inside of the oven vent using a lint-free cloth and isopropyl alcohol.
- Unlatch the heating elements.
- Fully open all lids.
- Allow the machine to cool for at least 10 minutes.
- Remove excess powder or glycerin buildup.
- Clean all residue using isopropyl alcohol.
- Close and latch the oven area.
- Clean the sensor using a lint-free cloth and isopropyl alcohol.
- Keep all covers closed to prevent dust and debris accumulation.
- Use a Phillips screwdriver to remove the screw from the glycerin container.
- Inspect glycerin buildup inside the container.
- Clean the container using isopropyl alcohol.
- Reinstall and secure the screw.