Before you start
What you need
- Print head
- Prepare the cleaning solution: Run the solution through a disk filter to remove contaminants.
- Prepare the storage box: Pour cleaning solution to the designated fill line.
- Submerge the print head: Carefully submerge ONLY the face of the print head.
- Connect the syringe: Attach the tube from the printer to the print head.
- Pull cleaning solution (Reverse Waterfall): Pull slowly with the syringe.
- Refill and repeat: Refill the storage box with fresh solution.
- Drain old solution: Pour remaining solution out of the print head box.
- Prepare fresh solution: Pour fresh cleaning solution into a clean cup.
- Push cleaning solution (Standard Waterfall): Connect the syringe to the print head.
- Verify flow: Cleaning solution should visibly flow out of the print head face.
- Repeat: Perform this step for EACH channel.
- Dry the print head: Use a lint-free cloth.
- Inspection: Ensure no excess solution remains.
- Print head storage box (OEM recommended)
- Lint-free cloth
- Syringe
- Cleaning solution
- Two cups (clean solution + waste solution)
- If you do not have the OEM storage box, you may use any clean container as long as:
- The print head face can be submerged
- NO electrical components contact liquid
- Avoid ALL liquid contact with electrical connection points on the print head.
- 00:01:01 STEP 1 – REVERSE WATERFALL (MUST BE DONE FIRST)
- If unsure how to do this, stop and contact tech support.
- Lightly warm the solution in a microwave.
- Warm only — DO NOT overheat.
- Verify the height does not exceed the safe level.
- Test placement before inserting the print head.
- Ensure no electrical components touch the solution.
- Push the tube fully in for a solid seal.
- Continue pulling until bubbles appear in the syringe.
- Bubbles indicate the channel has been fully pulled.
- Dispose of used solution into a separate waste container.
- Keep the print head face submerged at all times.
- Repeat for EACH channel.
- 00:02:33 STEP 2 – STANDARD WATERFALL
- Use a clean syringe to draw a full syringe.
- Hold the print head over the waste container.
- Slowly and gently push solution through the channel.
- Do NOT force the syringe.
- 00:03:05 FINAL CLEANUP
- GENTLY dab the bottom of the print head.
- Do NOT wipe the face directly.
- Verify electrical contacts are completely dry.