Miro 13 Max Powder Shaker Oven - Maintenance Guide

  1. 0:02Overview and Maintenance Categories
  2. 0:35Daily Maintenance Tools
  3. 1:08Daily Maintenance Procedure
  4. 3:00Filter Replacement Recommendation
  5. 5:13Reassembly and Storage
  6. 5:51Monthly and As-Needed Maintenance Tools
  7. 7:04Completion
Written steps11

Overview and Maintenance Categories

Watch this part0:02

What you need

  • Maintenance categories: Daily, Weekly, As Needed
  • Purpose: Prolong equipment life and prevent glycerin overflow
  • Glycerin is produced during ink evaporation in the curing process and can accumulate as liquid residue

Daily Maintenance Tools

Watch this part0:35

What you need

  • Isopropyl alcohol
  • Lint-free cloths
  • Gloves
  • Brush

Daily Maintenance Procedure

Watch this part1:08
  1. Open the main oven chamber.
  2. Turn off all power except for the main power and purifier.
  3. Allow the purifier to run for an additional 5 minutes to cool the oven chamber.
  4. Once the heat chamber temperature decreases, detach the Miro 13 Max from the printer.
  5. Lower the preheating platen.
  6. Turn off the purifier and main power.
  7. Brush off excess powder from the oven chamber.
  8. Use a lint-free cloth and isopropyl alcohol to wipe the oven surface.
  9. Clean the sides of the oven where glycerin can collect.
  10. Pay extra attention to the right side of the oven near wiring connections.
  11. Wipe the top surface of the oven.
  12. Close the oven cover.
  13. Clean the outer filter cover.
  14. Open the filter cover and inspect surfaces around the fan.
  15. Remove any built-up glycerin around the fan area.

Filter Replacement Recommendation

Watch this part3:00

What you need

  • Purifier filter: replace monthly
  • Air vent filter: replace monthly
  • Fabric top cover: replace monthly
  • Contact a DTF Station dealer to purchase replacements and keep spares on hand

Powder Station and Platen Cleaning

What you need

  • Protect powder from air, moisture, and dust
  • Powder is effective for up to one year
  • Store powder around 70 F with humidity below 35%
  • Keep powder away from direct sunlight
  • Keep used powder separate and mix gradually with new powder
  1. Brush off powder from the preheating platen.
  2. Wipe the platen with isopropyl alcohol.
  3. Remove the media wheel from the powder station.
  4. Clean powder residue from the media wheel.
  5. Clean the rod with isopropyl alcohol if needed.
  6. Brush excess powder inside the powder station toward the bottom tray.
  7. Clean around the sensor area without scratching it.
  8. Gently wipe the sensor face with a lint-free cloth and isopropyl alcohol.
  9. Remove the bottom powder tray.
  10. Pour powder into a lidded container.

Reassembly and Storage

Watch this part5:13
  1. Insert the media wheel back into the powder station.
  2. Close the powder station cover.
  3. Cover the entire unit with an equipment cover.

Weekly Maintenance Tools

What you need

  • Isopropyl alcohol
  • Lint-free cloths

Weekly Maintenance Procedure

  1. Perform all daily maintenance steps.
  2. Use isopropyl alcohol and a lint-free cloth to clean the glycerin catch trays on both sides of the machine.
  3. Cover the entire unit with an equipment cover.

Monthly and As-Needed Maintenance Tools

Watch this part5:51

What you need

  • Brush
  • Replacement filters

Monthly and As-Needed Maintenance Procedure

  1. Regularly replace the purifier filter, air vent filter, and fabric top cover.
  2. Open the top filter cover.
  3. Remove the fabric cover and air filter from the top section.
  4. Open the purifier fan metal lid.
  5. Remove the filters beneath the lid.
  6. Clean the surrounding area as needed.
  7. Install the new filter.
  8. Close the purifier fan metal lid.
  9. Ensure the air filter is securely covering the surface from the outside.