Setup and Power On
Watch this part0:00- Position the machine in its desired location.
- Rotate the feet clockwise until they are firmly contacting the floor to reduce movement during operation.
- Rotate the emergency stop knob counterclockwise to release it.
- Flip the main power switch up to power on the machine.
- Move to the air compressor.
- Rotate the red handle to align with the tube to allow air flow.
- Pull the red power button upward to turn on the air compressor.
- Locate the air pressure control valve on the Fold Flex 100.
- Push the blue lock to the right to allow air to enter the machine.
- Check the air pressure indicator and verify it reads 04 PSI.
- Adjust the air pressure if the indicator does not read 04 PSI.
- Activate the machine using either the start button or the foot pedal.